Cyflwyniad Cynnyrch
Mae'r pwmp tanddwr solar AC/DC yn system pwmp dŵr modd deuol sy'n gydnaws â phŵer AC a DC. Gall weithredu'n uniongyrchol gan ddefnyddio pŵer DC o baneli solar neu fatris, neu gysylltu â grid pŵer AC confensiynol. Trwy reolwr deallus, mae'n nodi'r ffynhonnell pŵer yn awtomatig ac yn newid dulliau gweithredu, gan flaenoriaethu pŵer solar pan fo golau'r haul yn ddigonol, a newid yn ddi-dor i'r grid neu bŵer wrth gefn yn ystod dyddiau cymylog neu glawog neu gyda'r nos, gan sicrhau cyflenwad dŵr di-dor.
4/6SSC{2}AC/DCData Perfformiad
|
Nac ydw. |
Pwmp |
Rheolydd |
Paneli Solar |
|||||||
|
CÔD WASSERMANN |
Cyf.# |
R. llif (m³/h) |
Pŵer modur (HP) |
Camau |
Math Drive |
Pŵer (KW) |
Amrediad Foltedd AC (V) |
Ystod VOC (V) |
Amrediad Foltedd MPPT (V) |
|
|
431 |
4/6SSC17/1-A/D |
26m³/h-18m-150V-1100W |
17 |
1.5 |
1 |
AC/DC |
WAD solar 1.1kw |
80-280V |
80-430V |
150-350V |
|
432 |
4/6SSC17/2-A/D |
30m³/h-31m-180V-1500W |
17 |
2 |
2 |
AC/DC |
WAD solar 1.5kw |
80-280V |
80-430V |
180-350V |
|
433 |
4/6SSC17/3-A/D |
30m³/h-52m-280V-2200W |
17 |
3 |
3 |
AC/DC |
WAD solar 2.2kw |
80-280V |
80-430V |
280-350V |
|
434 |
4/6SSC17/4-A/D |
30m³/h-70m-300V-3000W |
17 |
4 |
4 |
AC/DC |
3kw solar WAD |
80-280V |
80-430V |
300-350V |
|
435 |
4/6SSC30/2-A/D |
52m³/h-32m-280V-2200W |
30 |
3 |
2 |
AC/DC |
WAD solar 2.2kw |
80-280V |
80-430V |
280-350V |
|
436 |
4/6SSC30/3-A/D |
52m³/h-48m-300V-3000W |
30 |
4 |
3 |
AC/DC |
3kw solar WAD |
80-280V |
80-430V |
300-350V |
|
437 |
4/6SSC15/5-A/D |
30m³/h-70m-530V-3000W |
15 |
4 |
5 |
AC/DC |
3kw solar WAD |
260-480V |
200-900V |
480-650V |
|
438 |
4/6SSC18/5-A/D |
36m³/h-88m-530V-4000W |
18 |
5.5 |
5 |
AC/DC |
4kw solar WAD |
260-480V |
200-900V |
480-650V |
|
439 |
4/6SSC18/6-A/D |
36m³/h-105m-530V-5500W |
18 |
7.5 |
6 |
AC/DC |
WAD solar 5.5kw |
260-480V |
200-900V |
480-650V |
|
440 |
4/6SSC18/7-A/D |
36m³/h-122m-530V-7500W |
18 |
10 |
7 |
AC/DC |
WAD solar 7.5kw |
260-480V |
200-900V |
480-650V |
|
441 |
4/6SSC17/7-A/D |
36m³/h-175m-530V-9200W |
17 |
12.5 |
7 |
AC/DC |
WAD solar 9.2kw |
260-480V |
200-900V |
480-650V |
|
442 |
4/6SSC18.5/7-A/D |
36m³/h-190m-530V-11000W |
18.5 |
15 |
7 |
AC/DC |
WAD solar 11kw |
260-480V |
200-900V |
480-650V |
|
443 |
4/6SSC31/4-A/D |
52m³/h-48m-530V-3000W |
31 |
4 |
4 |
AC/DC |
3kw solar WAD |
260-480V |
200-900V |
480-650V |
|
444 |
4/6SSC30/4-A/D |
52m³/h-64m-530V-4000W |
30 |
5.5 |
4 |
AC/DC |
4kw solar WAD |
260-480V |
200-900V |
480-650V |
|
445 |
4/6SSC30/5-A/D |
52m³/h-80m-530V-5500W |
30 |
7.5 |
5 |
AC/DC |
WAD solar 5.5kw |
260-480V |
200-900V |
480-650V |
|
446 |
4/6SSC30/6-A/D |
52m³/h-96m-530V-7500W |
30 |
10 |
6 |
AC/DC |
WAD solar 7.5kw |
260-480V |
200-900V |
480-650V |
|
447 |
4/6SSC30.1/6-A/D |
52m³/h-128m-530V-9200W |
30.1 |
12.5 |
6 |
AC/DC |
WAD solar 9.2kw |
260-480V |
200-900V |
480-650V |
|
448 |
4/6SSC30.2/6-A/D |
52m³/h-160m-530V-11000W |
30.2 |
15 |
6 |
AC/DC |
WAD solar 11kw |
260-480V |
200-900V |
480-650V |
|
449 |
4/6SSC35/2-A/D |
65m³/h-40m-530V-4000W |
35 |
5.5 |
2 |
AC/DC |
4kw solar WAD |
260-480V |
200-900V |
480-650V |
|
450 |
4/6SSC35/3-A/D |
65m³/h-60m-530V-5500W |
35 |
7.5 |
3 |
AC/DC |
WAD solar 5.5kw |
260-480V |
200-900V |
480-650V |
|
451 |
4/6SSC35/4-A/D |
65m³/h-80m-530V-7500W |
35 |
10 |
4 |
AC/DC |
WAD solar 7.5kw |
260-480V |
200-900V |
480-650V |
|
452 |
4/6SSC32/4-A/D |
65m³/h-100m-530V-9200W |
32 |
12.5 |
4 |
AC/DC |
WAD solar 9.2kw |
260-480V |
200-900V |
480-650V |
|
453 |
4/6SSC32.5/4-A/D |
65m³/h-120m-530V-11000W |
32.5 |
15 |
4 |
AC/DC |
WAD solar 11kw |
260-480V |
200-900V |
480-650V |
|
454 |
4/6SSC46/3-A/D |
95m³/h-65m-530V-7500W |
46 |
10 |
3 |
AC/DC |
WAD solar 7.5kw |
260-480V |
200-900V |
480-650V |
|
455 |
4/6SSC45.5/3-A/D |
95m³/h-85m-530V-11000W |
46 |
15 |
3 |
AC/DC |
WAD solar 11kw |
260-480V |
200-900V |
480-650V |
Cromliniau Nodweddiadol


4/6SSC{2}AC/DCDimensiwn
![]() |
Nac ydw. |
CÔD WASSERMANN |
Rhyddhau (Mewn) |
A |
B |
C |
D |
||||
|
mewn |
mm |
mewn |
mm |
mewn |
mm |
mewn |
mm |
||||
|
431 |
4/6SSC17/1-A/D |
3" |
11 |
278 |
10 |
258 |
21 |
536 |
5.7 |
145 |
|
|
432 |
4/6SSC17/2-A/D |
3" |
13 |
324 |
10 |
258 |
23 |
582 |
5.7 |
145 |
|
|
433 |
4/6SSC17/3-A/D |
3" |
15 |
370 |
11 |
278 |
26 |
648 |
5.7 |
145 |
|
|
434 |
4/6SSC17/4-A/D |
3" |
16 |
416 |
12 |
298 |
28 |
714 |
5.7 |
145 |
|
|
435 |
4/6SSC30/2-A/D |
3" |
17 |
422 |
11 |
278 |
28 |
700 |
5.7 |
145 |
|
|
436 |
4/6SSC30/3-A/D |
3" |
20 |
517 |
12 |
298 |
32 |
815 |
5.7 |
145 |
|
|
437 |
4/6SSC15/5-A/D |
3" |
16.4 |
416 |
12 |
298 |
28.1 |
714 |
3.9/5.7 |
100/145 |
|
|
438 |
4/6SSC18/5-A/D |
3" |
18 |
462 |
13 |
318 |
31 |
780 |
5.7 |
145 |
|
|
439 |
4/6SSC18/6-A/D |
3" |
20 |
508 |
13 |
338 |
33 |
846 |
5.7 |
145 |
|
|
440 |
4/6SSC18/7-A/D |
3" |
22 |
554 |
16 |
398 |
37 |
952 |
5.7 |
145 |
|
|
441 |
4/6SSC17/7-A/D |
3" |
16.4 |
416 |
12 |
298 |
28.1 |
714 |
3.9/5.7 |
100/145 |
|
|
442 |
4/6SSC18.5/7-A/D |
3" |
22 |
554 |
16 |
398 |
37.5 |
952 |
3.9/5.7 |
100/145 |
|
|
443 |
4/6SSC31/4-A/D |
3" |
20 |
517 |
12 |
298 |
32.1 |
815 |
3.9/5.7 |
100/145 |
|
|
444 |
4/6SSC30/4-A/D |
3" |
24 |
612 |
13 |
318 |
37 |
930 |
5.7 |
145 |
|
|
445 |
4/6SSC30/5-A/D |
3" |
28 |
707 |
13 |
338 |
41 |
1045 |
5.7 |
145 |
|
|
446 |
4/6SSC30/6-A/D |
3" |
32 |
802 |
16 |
398 |
47 |
1200 |
5.7 |
145 |
|
|
447 |
4/6SSC30.1/6-A/D |
3" |
32 |
802 |
16 |
398 |
47.2 |
1200 |
3.9/5.7 |
100/145 |
|
|
448 |
4/6SSC30.2/6-A/D |
3" |
32 |
802 |
16 |
398 |
47.2 |
1200 |
3.9/5.7 |
100/145 |
|
|
449 |
4/6SSC35/2-A/D |
3" |
17 |
422 |
13 |
318 |
29 |
740 |
5.7 |
145 |
|
|
450 |
4/6SSC35/3-A/D |
3" |
20 |
517 |
13 |
338 |
34 |
855 |
5.7 |
145 |
|
|
451 |
4/6SSC35/4-A/D |
3" |
24 |
612 |
16 |
398 |
40 |
1010 |
5.7 |
145 |
|
|
452 |
4/6SSC32/4-A/D |
3" |
22 |
568 |
16 |
398 |
38 |
966 |
3.9/5.7 |
100/145 |
|
|
453 |
4/6SSC32.5/4-A/D |
3" |
22 |
568 |
16 |
398 |
38 |
966 |
3.9/5.7 |
100/145 |
|
|
454 |
4/6SSC46/3-A/D |
4" |
22 |
568 |
16 |
398 |
38 |
966 |
5.7 |
145 |
|
|
455 |
4/6SSC45.5/3-A/D |
3" |
22 |
568 |
16 |
398 |
38 |
966 |
3.9/5.7 |
100/145 |
|
Affeithwyr am Ddim

Pecynnu

Nodweddion
- Mae technoleg modur a phwmp profedig yn sicrhau-dibynadwyedd hirdymor.
- Mae Olrhain Pwynt Pwer Uchaf (MPPT) yn gwneud y gorau o effeithlonrwydd pŵer mewnbwn.
- Mae -gwythiant cychwyn meddal yn atal morthwyl dŵr ac yn ymestyn oes y system.
- Mae modur magnet di-frws yn galluogi gosodiad hawdd a llai o waith cynnal a chadw.
- CE ardystiedig ar gyfer diogelwch a chydymffurfiaeth.
Mantais
- Mae gyriant modd deuol yn sicrhau cyflenwad pŵer di-dor.
Mae'r system yn nodi ac yn newid yn awtomatig rhwng pŵer grid AC a phŵer solar / batri DC, gan alluogi cyfatebolrwydd ynni. Rhoddir blaenoriaeth i ynni solar pan fo golau'r haul yn helaeth; yn ystod tywydd cymylog neu glawog neu gyda'r nos, mae'n newid yn awtomatig i bŵer grid neu bŵer wrth gefn, gan ddatrys yn llwyr y broblem o ymyrraeth cyflenwad dŵr mewn pympiau pŵer solar pur yn ystod cyfnodau cymylog hir.
- Effeithlonrwydd uchel, deallusrwydd ac arbed ynni
Mae'r rheolydd deallus adeiledig yn cynnwys swyddogaethau addasu MPPT a foltedd, gan wneud y mwyaf o'r defnydd o ynni'r haul a chyflawni cychwyn meddal ac optimeiddio pŵer yn y modd AC, gan arwain at arbed ynni cyffredinol o 30% -50%.
Senarios Cais




MAE'N BLESER CYDWEITHREDU GYDA CHI
- Stoc
- Cefnogaeth ar ôl gwerthu
- Dosbarthu cyflym: 15-30 diwrnod
- Cyfarwyddyd gosod clir
- Dim MOQ
- Cefnogaeth logisteg
- gwarant 18 mis
- Addasu, OEM / ODM ar gael
- Ymateb cyflym
- Rheolwr gwerthu cymwys
- Telerau talu hyblyg
- cymorth technegol 24/7
- Sampl ar gael

FAQ
Cynnal a chadw pympiau tanddwr solar AC/DC yn rheolaidd
1. Cynnal a Chadw System Ynni:Glanhewch lwch, eira neu falurion o wyneb y paneli solar yn rheolaidd i sicrhau trosi ynni effeithlon. Gwiriwch fod y cysylltiadau llinell AC/DC yn ddiogel i atal ocsidiad neu lacio.
2. Monitro Gweithrediad Offer:Arsylwch y goleuadau dangosydd rheolydd neu sgrin arddangos i gadarnhau bod y modd cyflenwad pŵer yn newid fel arfer ac nid oes unrhyw negeseuon larwm. Sylwch ar unrhyw synau anarferol o'r pwmp dŵr yn ystod y llawdriniaeth a chofnodwch nhw'n rheolaidd.
3. Diogelu'r Amgylchedd Penodol:Cadwch y lloc rheolydd yn sych ac wedi'i awyru'n dda, gan osgoi golau haul uniongyrchol neu law. Mewn rhanbarthau oer, draeniwch y dŵr o'r pibellau pan na chaiff ei ddefnyddio; mewn amgylcheddau tywodlyd, gwiriwch a yw'r hidlydd mewnfa ddŵr yn rhwystredig, ac ati.
Tagiau poblogaidd: pwmp tanddwr solar ac dc, gweithgynhyrchwyr pwmp tanddwr solar Tsieina ac dc, cyflenwyr, ffatri